4-7-10 DUPLEX GENERATE MODE (FM/AM-1200S ONLY)
In Duplex Generate Mode of operation, the signal
is present at the T/R
Connector (11) only.
There is NO signal
present at the DUPLEX Output
Connector (14).
The output frequency at the T/R Connector (11) is the
RF setting plus the OFFSET frequency with the output level controlled by
the RF Level Attenuator Control
( 9) and RF Level Attenuator Vernier
Control
(10).
The FM/AM-1200S receiver will monitor the FM/AM-1200S
generator.
\NOTE\
FM/AM-1200S is forced into the generate mode
and will
not switch to receive mode when trans-
mitting into T/R Connector (11).
EXAMPLE:
RF Setting
=
OFFSET Setting
=
Output Frequency @ T/R
157.77 MHz
-5.26 MHz
Connector ( 11)
=
152.51 MHz
4-43d