IFR FM/AM-1200A Operation Manual page 135

Communications service monitor
Table of Contents

Advertisement

STEP
7.
5-18
07
PROCEDURE
Output levels at the DUPLEX Output Connector (14)
with the Tracking Generator installed are:
Track High:
-3 dBm ±5 dB
Track
Med:
-15 dBm ±7 dB
Track
Low:
-40 dBm +5/-10 dB
select the desired output level.
Figure 5-5
Typical Tracking Generator Display of a
Notch Filter notch
HORIZONTAL/DISPERSION
BANDWIDTH
HORIZONTAL SWEEP
SPEED*
1 kHz/DIV
300 Hz
10 niS/Div
2 kHz/DIV
300 Hz
10 mS/Div
5 kHz/DIV
3 kHz
5 mS/DIV
10 kHz/DIV
3 kHz
5 mS/DIV
20 kHz/DIV
30 kHz
5 mS/DIV
50 kHz/DIV
30 kHz
5 mS/DIV
. 1 MHz/DIV
30 kHz
5 mS/DIV
. 2 MHz/DIV
30 kHz
5 mS/DIV
. 5 MHz/DIV
30 kHz
5 mS/DIV
1 MHz/DIV
30 kHz
5 mS/DIV
Table 5-5
Horizontal Sweep Selector Control (Analyzer
Dispersion Control) Settings and Horizontal Sweep
Speed
*All Sweep Speeds are variable by using the Horizontal Sweep
Vernier Control (25).