IFR FM/AM-1200A Operation Manual page 78

Communications service monitor
Table of Contents

Advertisement

STEP
PROCEDURE
------------------------------------------------------------------------
2.
Modulate transmitter under test with a fixed 1 kHz tone.
[Non!
FM/AM-1200S/A 1 kHz Tone Generator (fixed)
function should be used as a modulation
source.
Measurement accuracy is dependent on accuracy of
1 kHz tone.
3.
Position Modulation METER Control (4) to ''DIST".
4.
Connect coax cable between FM/AM-1200S/A DEMOD Connector (16)
and EXT MOD/SINAD Connector (15).
5.
Monitor DIST Level on top scale of MODULATION Meter (1).
6.
Place VERTICAL Attenuator Selector Control (24) to "RESID''
position to observe residual distortion on oscilloscope.