4-7
DUPLEX OPERATION
FM/AM-1200S/A CONNECTORS
AND INDICATORS APPLICABLE
TO DUPLEX OPERATION:
1
MODULATION Meter
11
T/R Connector
14
DUPLEX Output Connector
15
EXT MOD/SINAD Connector
19
MIC/ACC Connector
20
SCOPE/DVM Connector
31
CRT Display
33
LOCK Lamp
36
FREQ ERROR Meter
37
VFD
Figure 4-3
FM/AM-12005/A Front Panel Controls
Applicable to Duplex Operation
CONTROL
3
MODULATION Select Control
4
Modulation METER Control
9
RF Level Attenuator Control
10
RF Level Attenuator Vernier
Control
18
Keyboard
22
PWR/OFF/BATT Switch
24
VERTICAL Attenuator
Selector Control
26
HORIZONTAL Sweep
Selector Control
32
GEN/LOCK Control
35
FREQ ERROR Meter Range
Selector Control
39
MODE Selector Control
40
VOLUME Control
Table 4-8
FM/AM-1200S/A Front Panel Controls
Applicable to Duplex Operation
[NOTE\
SETTING
"FM NAR"
"kHz/%X10
position 6"
"-50 dBm'
•. 5
v •
"RF Frequency
150.2000 MHz"
"PWR' or ''BATT''
"2 kHz/%X10"
"1 mS/Div"
"LOCK"
" 1 0 K'
" G
EN "
as req'd
For Accurate Power Meter measurements, set RF Level
Attenuator Control (9) to any position other than
-20 dBrn.
4 -4 0
06