4-11-3 ALLOWABLE RS-232 COMMAND FORMATS
FM/AM-1200S/A communication with an external controlling device requires
use of the allowable RS-232 command formats listed in Table 4-12.
COMMAND
DEFINITION
EXAMPLE
FUNC=VALUE
Sets memory location 0 of
AFF=12345 .6
(CR or Colon)*
selected function to value
Sets Tone Generator
selected and executes i t •
memory location
0
to 12345.6 Hz and
executes it.
Func(nn)=VALUE*
Programs memory location
RFF6=345 .6666
FUN C
(CR
4-52
02
(CR
FUN C
or
FUN C
( 0
to 15 ) of selected
Programs RF Fre-
function to value selected.
quency memory l oca-
Does not execute selection.
tion 6 to 345.6666
MHz.
or Colon)*
Executes val u e of selected
DTMF:
function stored i n memory
Executes value
location 0 •
stored i n DTMF
memory location \L
( n n )
Executes value of selected
PULSE 12:
Colon)*
memory location
( 0
to 15 )
Executes value
of selected function.
stored i n memory
location 12 of the
PULSE function.
(nn)?*
Displays on V FD the value
R F F2?
*
of selected memory location
Displays value of
( 0
thru 15 ) of the selected
RF memory location
function.
2 •
AFF10?
Displays value of
Tone Generator
memory location 10.
FUNC = AFF, DPX, DCS, DTM, DTMF, MTR1, MTR2, PUL, PULS,
PULSE, RFF or WAV.
(nn) = function preset number (0 thru 15).
Linefeed, Carriage Return or Colon= terminates command.
Value = function command value field.
Table 4-12
Allowable Command Formats