7.5

DIP switch settings

DANGER
High voltages.
u
Danger of fatal electric shock.
u
Ensure safe isolation from the power supply.
DIP-switches configure the current setting of the charger.
Fig. 5
DIP switch up/ON = 1
DIP switch down/OFF = 0
DIP-switch factory setting: 1100
NOTE
Changes to the DIP switch settings become active after
restarting the charging station.
NOTE
DIP switches 3 and 4 are set at the factory. Switches 3
and 4 must be left set to 0.
II Webasto Pure EN
Description
16 A (1-phase)
32 A (1-phase) *
16 A (3-phase) **
32 A (3-phase)
*
The charging current is limited to 20 A in the factory in
the case of a 22 kW variant with 1-phase charging. See
chapter 8.3, "Deactivate charging current limit (option 2)"
on page 8. * The charging current is already limited to
16 A in the factory in the case of an 11 kW variant.
WCH000011A
**
A Webasto Pure programmed for 11 kW cannot be set to
22 kW with the DIP switches.
7.6
7.6.1
Document the results of the checks and measurements carried
out during initial start-up corresponding to the applicable in-
stallation requirements and standards.
The local regulations relating to operation, installation and en-
vironmental protection also apply.
7.6.2
u
Remove material residues from the connection area.
u
Check that every screw is correctly tightened and every
clamp is correctly engaged.
u
Fit the lower cover.
u
Secure the bottom cover with the mounting screws; Tighten
the mounting screws to the stop. See chapter 7.3, "Installa-
tion" on page 5.
u
Switch on power supply.
– Start sequence is activated (duration up to 60 seconds).
– LED indicator flashes in colours at 1 second intervals.
Red/green/blue. See LED indicators, operating status N1.
u
If necessary, unlock charging station with key-operated
switch.
u
Perform initial operation check and record measured values
in test log. An EV simulator is used for the measurement at
the charging coupling.
u
Simulate and test the individual operating and protection
functions with the EV simulator.
u
Connect the charging cable to the vehicle.
WCH0000012A
– The LED changes from blue to green.
8
8.1
See also Key-operated switch.
ü Charging station switched on.
ü LED indicator is blue.
ü Key-operated switch set to ON.
1
1- or 3-
16 or 32
phase
A per
phase
0
0
1
1

Initial start-up

Safety check
Start-up procedure

Settings

NOTE
It is necessary to complete the following procedures
within a certain time, therefore read through all the
steps before starting the procedure.

To activate programming mode

Settings | 8
Switch
2
3
4
Capa-
city
Factory
setting
0
0
0
3.7 kW
1
0
0
7.4 kW
0
0
0
11 kW
1
0
0
22 kW
7 / 13