To Reserve Slots

1. From the Default screen, press the Enter button to display the Main
menu.
2. From the Main menu, scroll down to the Configure menu and press the
Enter button to display the following Configure submenu:
υ SCSI Options:
Library Options
Date and Time
Set Element Base
3. Scroll down to Library Options and press the Enter button.
4. Scroll down to Reserved Slots and press the Enter button. The
following screen appears:
Configuration:
*Stand Alone
.
.
.
.
Baud Rate:
*38,400
υ Reserved Slots:
*0
5. Scroll down to the last line and specify the number of slots you are
reserving. Press the Enter button to save.
If your software license limits the number of usable slots in the magazine,
you must reserve the remaining slots. You can use any of the reserved slots
to store a cleaning cartridge (see Chapter 5, "Maintenance").
6. Press the Escape button repeatedly to return to the Default screen. Your
choice takes effect the next time the Library is rebooted.