Dansensor
MAP Check 3 Vacuum
®
COM-1/COM-2 Cables
The 9-pole communication cables should have the following pin connections (female
connectors):
COM-1 Main (MASTER) RS232 communication port (DTE Male)
Pins/text
2
"RxD"
3
"TxD"
5
"GND"
7
8
9
"+5V"
COM-2 Main (SLAVE) RS232 communication port (DTE Male)
Pins/text
2
"RxD"
3
"TxD"
5
"GND"
NOTE! COM-1 and COM-2 communication ports are not galvanic isolated i.e. "GND"
is connected to Mains ground and the chassis. Avoid ground loops during
installation.
EN
1
2
3
4
5
6
7
8
9
Description
Receive data, serial data input from packaging machine / PLC
Transmit data, serial data output to packaging machine / PLC
Ground, signal ground
CURRENTLY NOT USED
CURRENTLY NOT USED
Voltage supply +5V. Max. 250mA (fused)
Description
Receive data, serial data input from slave device - e.g. MAP Mix
Provectus
Transmit data, serial data output to slave device - e.g. MAP Mix Provectus
Ground, signal ground
User Guide
29
P/N 320598-G
11/2019
Need help?
Do you have a question about the AMETEK Dansensor MAP Check 3 Vacuum and is the answer not in the manual?