I/O Signals For Machine Control - Mocon AMETEK Dansensor MAP Check 3 Vacuum User Manual

Table of Contents

Advertisement

Dansensor
MAP Check 3 Vacuum
®

I/O signals for machine control

"EVAC" signal
"GAS" signal
"READY" relay
"ALARM" relay
"WARNING" relay
Packaging
Machine
Packaging
Machine
EN
"SIMPLE INSTALLATION"
Uses only "ALARM" signal to
control the packaging machine
I/O Cable
1
White
"GAS" signal
2
Brown
3
Green
"EVAC" signal
4
Yellow
5
Grey
"ALARM" signal
7
Blue
"FULL INSTALLATION"
Uses all signals to control
the packaging machine
I/O Cable
1
White
"GAS" signal
2
Brown
3
Green
"EVAC" signal
4
Yellow
5
Grey
"READY" signal
7
Blue
8
Red
10
Purple
11
Grey/Pink
13
White/Green
User Guide
(Closed when no alarm)
(Closed when no alarm)
(Closed when no warning)
(Closed when ready)
P/N 320598-G