Chapter 6 — Advanced Confi guration

alerts Section

Objects enabled by default
- cutter
- headlifted
- ribbonend
- paperend
- ribbonlow
- paperlow
Objects disabled by default
- lts
- pause
- setup
- error
- break
- job-complete Sends alert when all labels in a print feed batch are
- odometer
Value Syntax
(enabled|disabled,<integer>,seconds|occurrences,
<text string>)
Example
SETUP "alerts","cutter","(enabled,9,seconds,Error
- Cutter Error)"

lan1 Section

Objects starting with a dot (.) cannot be read if the current user does
not have rights to read/set protected lan1 settings. Objects starting with
a plus sign (+) on the other hand, signify that all users can change the
setting.
Objects
ALERT_REC
72
Alerts if cutter error.
Alerts if head lifted and printfeed.
Alerts if ribbon end and printfeed.
Alerts if paper end and printfeed.
Alerts if ribbon low and printfeed.
Alerts if paper low and printfeed.
Sends alert when the printer is waiting for a label to
be taken.
Sends alert if a batch printing is paused.
Sends alert if Setup Mode is entered via the printers
internal keyboard.
Sends alert when a Fingerprint/Direct Protocol error
occurs (before giving control to the error-handler).
Sends alert if the user breaks the program or if an error
breaks Th e running program, that is, it is not sent after
stop or breakpoint.
started.
Alerts on diff erent service intervals depending
on the odometer count1 value.
Description
To address. Defi nes to whom the Alert
messages should be sent.