Read Local Device Address; Set Shutdown Timing; Clear Link Key Table - Intermec 6822P User Manual

80-column printer
Table of Contents

Advertisement

6820 Series 80-Column Printer User's Manual
Appendix B — Bluetooth Configuration Commands and Specifications

Read Local Device Address

Command
Description
Returns
Note: This command responds with the requested data, only
not the "ACK<CR>".
Example:
Sent: "V1<CR>"
Received: "v1%00%2C%C6%03%45%39"

Set Shutdown Timing

Command
Description
Range
Default
Example

Clear Link Key Table

Command
Description
Default
Example
V1<CR>
Displays the local device address
"v1%xx%xx%xx%xx%xx%xx<CR>"
T0<Time in Minutes><CR>
"Time" – Integer value – 0 implies never expire the
timer
0-270 minutes
120
"T0120<CR>" This sets the shutdown timer to 120
minutes.
B0<CLR><CR>
Clear Pair or Bonding command cleans up
all of the link key and Bluetooth address
combination PSKEYs.
None
"B0CLR<CR>" This clears all saved link
keys.
127