Inspection - Yamaha YZF1000RJ Service Manual

Hide thumbs Also See for YZF1000RJ:
Table of Contents

Advertisement

THERMosTAT1c vALvE
l c ooLI
~
I
J
0
--©
323 003
s1-------1
8
mm
(0.31
in)
71° ± 2°C
85°C
(160°
±
3.6°F)
(185°F)
323-002
5 - 10
11.Remove:
• Thermostatic valve housing
G)
• 0-ring
12.Remove:
• Thermostatic valve cover
G)
• Thermostatic valve®
EB502010
INSPECTION
1.lnspect:
• Thermostatic valve
G)
Valve does not open at 69
~
73°C (156.2
~
163.4°F)
Replace.
**********************************
Inspection steps:
• Suspend the thermostatic valve in a ves-
sel.
• Place an accurate thermometer in the
water.
•While stirring the water observe the ther-
mometer's indicated temperature.
**********************************
G)
Thermometer
®Water
®
Thermostatic valve
@Vessel
~
CLOSE
[ID
OPEN
NOTE: - - - - - - - - - - - -
The thermostatic valve is sealed and its set-
ting requires specialized work. If its accu-
racy is in doubt, replace it. A faulty unit
could cause serious overheating or over-
cooling.