Connecting The Data Cable With Projector And Chillers - Barco XDL Installation Manual

Table of Contents

Advertisement

Note: The circuit is pressurized which makes it sometimes difficult to insert the hoses.
Tip: First move the latch (reference 1
hose. Then release the latch and push the hose further until the latch locks.
Image 5–7 Left: Male hose connection, right: Female hose connection
CAUTION: Do not interchange the different cooling circuits with each other! Otherwise the system
will fail.
CAUTION: The minimum bend radius of the hoses is 30 centimeter.
5.4 Connecting the data cable with projector and
chillers
What has to be done?
Next to connecting the hoses, the communication port of the chillers has to be connected with each other and
with the projector.
Depending on the projector model one or two chillers are required! For the XDL-4K30 series projector one
chiller has to be installed. The XDL-4K60/75 series needs two chillers.
Required parts
One long (10 meter) communication cable with SUBD Male/Female 15 pins plugs.
One short (5 meter) communication cable with SUBD Male/Female 15 pins plugs (only if two chillers are
required).
How to connect the communication ports of the chillers with the projector?
1.
Does the system contain two chillers?
► If yes,
connect the output port of one chiller (reference 1
chiller(reference 2
Image
► If no,
proceed with the next step.
2.
Connect the output port of the chiller (reference 3
(reference 4
Image
5–8). Use for this a long communication cable.
Tip: Guide the long communication cable together with the hoses.
Image
1
5–8). Use for this a short communication cable.
5–7) away from the connection while coupling the
1
Image
5–8) with the input port of the other
Image
5–8) with the communication port of the projector
Installation procedures
R5906150 /05
XDL
49