Three Phase Power Input Configuration Of The Projector - Barco XDL Installation Manual

Table of Contents

Advertisement

Installation procedures
Note: Only remove the shunt wires from these pins which have to be connected with an external
safety interlock device. All other shunt wires must remain in place.
Note: Maximum two external safety interlock devices can be connected. These interlock
devices must have double pole normal open contacts. So, for normal operation of the projector
the normal open contacts are pushed into the closed state to close the circuit and thus enabling
the activation of the PSU of the lasers.
The internal master key can be extended with a single pole external master key (MK).
4.
Insert the 10 pole terminal block back in its socket. Use a small screw driver to fixate the terminal block.
5.
Insert the cable(s) in the cable tie located below the terminal block (reference 5
5
Image 5–12
6.
Install the cover of the mains compartment.
5.7 Three phase power input configuration of the
projector
About the power input
The projector power input can be configured for a power supply of 200-240V / 346-415V in a Y configuration
(3W+N+PE) or for 200-240V in a Δ configuration (3W+PE). Before operating the projector, place the links in
the correct position depending on the local power supply.
For a 3W+N+PE system, 346-415V is measured between the lines, 200-240V is measured between the lines
and the neutral.
For a 3W+PE system, 200-240V is measured between the lines.
52
R5906150 /05
XDL
10
9
8
7
6
5
4
3
2
1
Image
5–12).
B2
B1
MK
A2
A1

Advertisement