Chillers And Hoses - Barco XDL Installation Manual

Table of Contents

Advertisement

Component location
1
2
3
4
Image 2–3
1
Input & Communication interface
2
Beam stop button
3
Beam enable key
4
UPS sockets
5
Cover mains compartment
6
Valve coupling to connect with external chiller(s)
Air flow
The XDL series projector has two air flow channels (reference A & B) to cool the projector electronics. The air
intake is at the front side of the projector, the air outlet is at the back.
Image 2–4

2.2 Chillers and hoses

DMD
A digital micromirror device, or DMD, is an optical semiconductor that is the core of DLP projection
technology.
Introduction
The chillers are specially designed for the XDL projector. The chillers are controlled by the projector and
ensure that the ambient temperature of the lasers and DMDs is within specs. Without these chillers the
projector will not operate.
Depending on the projector model one or two chillers are required! For the XDL-4K30 series projector one
chiller has to be installed. The XDL-4K60/75 series needs two chillers.
11
10
9
8
7
5
6
A
B
7
Air inlet filter
8
Communication port with chillers.
9
Lens
10
Air outlet
11
Laser status light
12
Projector ID label
B
A
A
System overview
12
R5906150 /05
XDL
23

Advertisement

Table of Contents
loading