OPERATION
3. After selecting the desired mode, press function switch F6
and the mode is displayed in the center of the monitor dis-
play.
(Example: If power mode is selected: P)
4. After two seconds, the pilot monitor display at the top right
of the screen is highlighted in orange.
q
After two seconds, the screen returns to the standard
screen.
The monitor display highlighted in orange in Steps 4
returns to blue.
REMARK
When setting the working mode to B mode, to ensure safety,
the buzzer sounds and at the same time, the message in the
illustration on the right is displayed. When setting to the
breaker mode, always press function switch F6.
q
If function switch F5 is pressed, the breaker mode is not set,
and the screen returns to working mode selection screen.
NOTICE
When using the breaker, set to B mode. If B mode is not used, there is danger that the breaker may break.
DETAILED CONTROLS AND GAUGES
3-27