DETAILED CONTROLS AND GAUGES
q
When the monitor starts up, if the working mode setting is B
mode, the confirmation message on the right is displayed
and the buzzer sounds.
q
When starting up and staying in B mode, always press func-
tion switch F6 (Yes).
If you press F5 (No), the system starts up in E mode.
q
If you want to have automatic setting of the P, E, L, B or ATT mode when starting (optional default setting),
please ask your Komatsu distributor to change the setting.
Procedure for operation
1. If working mode selector switch (1) is pressed, the Working
Mode screen is displayed on the monitor.
2. Press function switches F3 or F4 at the bottom of the
screen or working mode selector switch (1) to change the
mode selection one at a time.
q
If no switch is touched for more than five seconds, the
selected working mode is automatically set as the
working mode and the screen changes to Steps 3 and
Steps 4.
REMARK
To return to the standard screen without changing the working
mode, press function switch F5.
3-26