HYDRAULIC QUICK COUPLER PIPING
HYDRAULIC QUICK COUPLER PIPING
Quick coupler operation can be dangerous. There is a risk of death to exposed persons. Follow these
instructions strictly.
1. Use only quick couplers which comply with European standard EN474. In particular, it must be possible to
confirm from the operator's position that the locking of the attachment or bucket has been completed.
2. Use only quick couplers which include a pilot operated check valve in the locking cylinder. This is to ensure
that there is no risk of the bucket or attachment coming loose in the case of loss of hydraulic pressure. If in
doubt consult the manufacturer of the quick coupler.
3. Read the instruction manual of the quick coupler carefully and follow the recommendations. If in doubt about
the installation or operation consult your Komatsu dealer.
4. The pressure regulation valve (2) allows the pressure at the quick coupler to be limited according to the quick
coupler manufacturer's recommendation. Check the specification of the quick coupler and ensure that the
valve is set appropriately.
5. Ensure that the quick coupler is installed by a suitably qualified technician. If in doubt contact your Komatsu
dealer.
LOCATIONS
2
1. Switch (See following page)
2. Adjustable pressure regulating valve
6-4
ATTACHMENTS ANDD OPTIONS
WARNING
6
3. Piping (quick coupler lock direction)
4. Piping (quick coupler release direction)
6
4
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc450lc-8

Table of Contents