Komatsu PC450-8 Operation & Maintenance Manual page 288

Hide thumbs Also See for PC450-8:
Table of Contents

Advertisement

MAINTENANCE PROCEDURE
Cleaning Outer Element
NOTICE
Before and after cleaning the element, do not leave or keep it in direct sunlight.
1. Open the right door of the machine, remove 6 hooks (2),
then remove cover (3).
NOTICE
q
Never remove the inner element (6). It will allow dirt to
enter and cause failure of the engine.
q
Do not use a screwdriver or other tool.
2. Hold the outer element (5), rock it lightly up and down and
to the left and right, and rotate the element to the left and
right to pull it out.
3. When the outer element (5) has been removed, check that
the inner element has not come out of position and is not at
an angle. If it is at an angle, insert your hand and push it in
straight.
4. After removing the outer element (5), cover the inner ele-
ment (6) with a clean cloth or tape to prevent dirt or dust
from entering.
5. Wipe off or brush off the dirt stuck to cover (3) and the
inside of the air cleaner body (7).
6. Remove any dirt or dust that is accumulated to evacuator
valve (4) installed to cover (3).
NOTICE
When cleaning the element, do not hit or beat it against
anything.
7. Direct dry compressed air (less than 0.69 MPa (7 kg/cm
to the outer element from inside along its folds, then direct
it from outside along its folds and again from inside.
1) Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace
the inner element at the same time.
2) Replace both inner and outer elements when the air cleaner clogging monitor (1) lights up soon after install-
ing the cleaned outer element even though it has not been cleaned 6 times.
4-22