OPERATION
3. On the working mode selection screen shown on the right,
select B Breaker and press switch F6.
q
On the working mode selection screen shown on the
right, it is possible to carry out the following operations
with switches F3 to F6.
F3: Moves to next item (1 line down).
F4: Moves to previous item (1 line up).
F5: Returns to user menu screen.
F6: Switches to setting screen for selected item.
4. The screen switches to the Breaker Select Menu.
q
Breaker setting selection menu
In breaker Select (a), the oil flow to be set in B mode
can be set to one of two set values.
q
Breaker flow setting menu
In the breaker flow setting (b), the oil flow to be set in B
mode can be changed.
DETAILED CONTROLS AND GAUGES
9EH9429a
3-45