Komatsu PC450-8 Operation & Maintenance Manual page 439

Hide thumbs Also See for PC450-8:
Table of Contents

Advertisement

HIGH REACH DEMOLITION EQUIPMENT 27M
Adjustment of boom angle warning sensor.
Boom
Proximity
switch
Proximity
switch
1. Loosen bolt (A) and adjust so that clearance between the
proximity switch and plate (1) is 5 - 8 mm.
2. Raise the boom to the maximum height, then gradually lower
it and stop the boom at the position where the indicator of the
inclination gauge is on line (P) between the green range and
red range.
3. Loosen bolt (B) and move plate (2) to the left or right to fix
dimension (L) so that the buzzer sounds at this position.
REMARK
Set clearance so that there is no contact even when the boom is
moved.
This adjustment should only be performed by Komatsu Certi-
fied Mechanics. Failure to adjust properly may result in an
unsafe operating condition.
Clearance
Plate
WARNING
Red range
OPERATION
Green range
Plate
7-29