Fayat Group DYNAPAC F2500C Application, Operation & Maintenance page 349

Table of Contents

Advertisement

Bleeding the filter
- Fill the opened filter housing with hy-
draulic oil up to approx. 2 cm below
the top edge.
- If the oil level drops, replenish
oil again.
Slow oil level reduction
A
of approx. 1 cm / min. is normal!
- If the oil level remains stable, slowly
insert the assembled unit with new fil-
ter element into the housing and tight-
en the cover mounting screws (A).
- Open the bleed screw (G).
- Place a transparent hose (H) onto
the bleed screw, ending in a suitable
container.
- Start the up drive engine at idle speed.
- Close the bleed screw (G) as soon as
the oil forced through the hose is clear
and therefore free of air bubbles.
The process from assembling the filter
A
cover to starting the drive engine should
take place in less than 3 minutes, as the
oil level in the filter housing otherwise
falls too far.
m
Ensure seal integrity is good after changing the filter.
Ventilation filter
The ventilation filter is contained in the
A
filler cap.
- Replace ventilation filter / filler cap.
A
G
H
I
F 60 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac f2500cs

Table of Contents