Mounting screws -
Outer auger bearing
Check tightening (7)
m
Following the running-in period, the
tightening torques of the outer auger
bearing mounting screws must be
checked.
- Tighten to the following torques if nec-
essary:
- (F): 210 Nm
m
If the auger's working width is changed,
the tightening check must be repeated
after the running-in period!