Pim_Info Action Table - HP Visualize b132L Service Handbook

B class
Hide thumbs Also See for Visualize b132L:
Table of Contents

Advertisement

Troubleshooting
Dealing with HPMC (Uncorrectable Error)
Table 8

PIM_INFO Action Table

Cache
Check
Check
Type Word
Word
0x80000000
0x40000000
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
0x20000000
N/A
Note 1
When more than one failed FRU is identified, run the appropriate diagnostics
to isolate the failed FRU.
Note 2
Replace the CPU board. See "HPMC Caused by a Data Cache Parity Error"
on page 90. for more information
Note 3
There are two possible sources of failure. First, replace the EISA controller. If
the error occurs again, replace the CPU board.
82
Bus
System
Check
Responder
Word
Word
N/A
N/A
0x00210003
0x00000000
0xEFFFFFF
0x00310007
0xF0000000
0xF7FFFFFF
0x00310007
0xF8000000
0xFBFFFFFF
0x00310007
0xFC000000
0xFFBFDFFF
0x00310007
0xFFFBE000
0xFFFBEFFF
0x00310007
0xFFFBF000
0xFFFFFFFFF
Action * See Note
1
See Note 2
Replace SIMM
Replace CPU board
Replace Optional
Graphics Card in
EISA slot
See Note 3
See Note 2
Replace CPU board

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

B180lB160lVisualize c360

Table of Contents