Decoder Notify; Figure 6-18 : Webeasy - Input Notify Tab - evertz 570J2K-HW-X19 User Manual

Multi channel j2k encoder-decoder
Table of Contents

Advertisement

570J2K-HW-X19
Multi channel J2K Encoder-Decoder
Port Link SFP2 Trap: This control allows the user to enable trap receiving when the port 2 is down
and an associated correction trap when the port is up.
Port Link Status SFP3: This status highlights Data 3 port status. If the port is up, the status will be
inactive / green. If the port is down, the status will be active / red.
Port Link SFP3 Trap: This control allows the user to enable trap receiving when the port 3 is down
and an associated correction trap when the port is up.
Port Link Status SFP4: This status highlights Data 4 port status. If the port is up, the status will be
inactive / green. If the port is down, the status will be active / red.
Port Link SFP4 Trap: This control allows the user to enable trap receiving when the port 4 is down
and an associated correction trap when the port is up.

6.11. DECODER NOTIFY

Figure 6-18 : WebEASY
- Input Notify Tab
®
6.10.1 Decoder Notification
For Decoder (1-9):
TS Input Missing: This will enable an alarm if transport stream is not detected on incoming multicast.
TS Sync Byte Missing: This will enable a fault on the transport stream on a missing sync byte.
Video PID Missing: This will enable a fault on the transport stream on a missing video PID.
Audio (1-4) PID Missing: This will enable a fault on missing audio (1-4) PID.
Page - 47