Canon imageRUNNER ADVANCE C9075S PRO Operating Information Manual page 363

Color digital multifunction imaging system
Hide thumbs Also See for imageRUNNER ADVANCE C9075S PRO:
Table of Contents

Advertisement

Place the spectrometer in the holder, press the button to calibrate the spectrometer,
and wait for 5 seconds.
Take 5 blank sheets of the same media you used for the calibration chart, and put
them underneath the calibration chart.
Measure the calibration sheet according to the instructions on the operator panel.
5.
Perform the following actions per color.
Position the spectrometer at the indicated position.
Hold down the spectrometer button and wait for the arrow.
Scan the column with patches smoothly in about 2 seconds.
Touch 'OK' to save the shading correction results and continue with the '2. Auto gradation
6.
adjustment' procedure.
Result
#
NOTE
In exceptional cases the '1. Shading correction' procedure fails with a 'Density out
of range' message. In that case you can first perform the '2. Auto gradation adjustment'
procedure before the '1. Shading correction' procedure. If the '1. Shading correction'
procedure still fails, contact your local service representative.
Calibrate the printer - 2. Auto gradation adjustment , on page 364
Calibrate the controller - 3. Media family calibration , on page 366
Calibrate the printer - '1. Shading correction'
Chapter 11 - Maintenance and calibration
363

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner advance c9065s pro

Table of Contents