D-4
ADS TRITON+ Manual
Note: Do not leave the Triton-Telog Comm Cable
connected to the TRITON+ monitor when the cable is not
also connected to an operational Telog Ru-33 or Ru-35.
This may cause the TRITON+ to remain awake,
unnecessarily consuming battery power and, consequently,
draining the battery pack. Therefore, disconnect the
Triton-Telog Comm Cable from the TRITON+ monitor
whenever the Telog unit is disconnected from the cable for
an extended period of time, removed from the manhole, or
out of service.

Ayyeka Wavelet 4R

Using a TRITON+ monitor to support the Ayyeka Wavelet 4R also
requires some limited configuration and setup.
Configuring the Monitor to Support the Wavelet
Configuring the TRITON+ to support the Wavelet 4R requires
setting three (3) additional parameters in Qstart
establishing a new location. Refer to Create and Configure the
Monitor Location in Chapter 4, Configuration and Activation, for
more information.
Modbus ID This represents the Modbus slave ID that will be
used by the Wavelet to indicate the specific monitor from
which to request the data. Numbers 1, 58, and 97 are restricted
Modbus IDs for the TRITON+ using Modbus RTU protocol,
but any other number between 2 and 247 may be chosen.
Modbus Delay Response This represents the amount of
time, in milliseconds, following the request before the monitor
will return the requested Modbus output data to the Wavelet.
ADS recommends maintaining the 10 ms default setting.
Enable This box must be checked to activate the Modbus
configuration.