Installation - ADS TRITON+ Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

6-2
ADS TRITON+ Manual

Installation

A typical field installation involving external power requires the
following:
An AC mains power line terminated at a pole or post close to
the manhole in which the monitor is installed
An AC distribution device (i.e., disconnect, fuse, or breaker
box) on the pole/post
An earth ground rod installed next to the pole/post bonded to
the AC distribution device
An AC to 24-volt DC converter (i.e., power supply). ADS
recommends a power supply available through ADS (p/n
508293), which works with worldwide AC power (94 – 240
VAC, 50 – 60 Hz). This power supply is provided
automatically as part of the XIO and XBUS, but must be
ordered for the ExPAC, when a power supply is required.
However, please note that the customer may use another AC-
to-DC converter/power supply, if desired, to support the
ExPAC, provided it can supply from 9 to 36 volts of power at a
minimum of 15 watts.
A power cable running between the external DC source (i.e.,
power supply) and the ExPAC power input. The customer
must supply this cabling of the appropriate length and
specifications
A properly rated enclosure to house and protect the ExPAC
and power supply
Note: Applications involving an XIO or XBUS do not
require an additional power cable or an enclosure because
they are included. The power is pre-run between the
power supply and ExPAC inside the XIO enclosure.
A communication cable (ADS p/n 8000-0378-xx, where xx
represents the required length of the cable) running between
the ExPAC/XBUS/XIO and the monitor