Temperature Subsystem
The following table contains general troubleshooting techniques for
the temperature subsystem corresponding to all sensors supporting
the TRITON+.
Note: Contact your ADS representative for further
diagnosis prior to replacing a sensor or monitor.
Maintenance and Troubleshooting
Pressure depth readings display a good pattern, but are
consistently incorrect.
Sensor physical offset may be incorrect.
Verify the sensor offset and reactivate with the correct
settings if necessary.
Individual PDEPTH_1 (_2) values consistently read 0
under wet pipe conditions.
Sensor may be faulty.
5-volt (blue) fuse on regulator may have blown.
Replace the Peak Combo Sensor.
Replace the 5-volt (blue) fuse on the regulator.
Caution: Do not connect a questionable sensor to
another monitor before verifying the integrity of the
sensor. A shorted sensor will blow the 5-volt (blue)
replacement fuse on the regulator in the monitor.
11-69