After installing the sensors and establishing communications, install
the ADS TRITON+
inside the manhole by an aluminum mounting bracket attached to
the monitor and bolted to the manhole wall or rim or by a hook
connected to the monitor that attaches to a rung. The following
procedures for monitor installation apply to most sites. However,
because manholes differ in many ways, some sites may require the
installer to implement slight modifications to the standard
installation technique.
Note: When ordering a monitor, please also indicate the
mounting option to ensure you receive the appropriate
installation hardware: wall/rim mount (ADS p/n I40-0009)
or rung mount (ADS p/n 8000-0021).
Before installing the monitor at the site, activate the monitor to
verify that the monitor is configured correctly for the application
and that the battery pack is operating at an adequate voltage. Make
any necessary changes to the configuration before mounting the
unit. Refer to Chapter 11, Maintenance and Troubleshooting, for
information on replacing the battery pack, when necessary.
Note: Manhole and sewer system work involves confined
space entry and is inherently dangerous. Therefore,
installers and technicians must comply with all federal,
state, and municipal regulations concerning confined space
entry. ADS is not responsible for any injuries, damages,
claims, or liability resulting directly or indirectly from the
®
monitor in the manhole. The monitor mounts