Broadcom NetXtreme Ethernet Adapter • Diagnostic User's Guide
-n<DEC>
-r<string>
10.84 mwrite
cmd: mwrite
Description: Write PHY registers via MII Management interface
Syntax: mwrtie <addr > <data>
Address range: 0x00 – 0x1F
Example:
1. Write 0x15 to MII register 2
0:> mwrite 2 15
10.85 mread
cmd: mread
Description: Read PHY registers via MII Management interface
Syntax: mread <begin>[-<end> | <len>]
Address range: 0x00 – 0x1F
Example:
1. Read MII register 0
0:> mread 0
00:
1100
2 Read MII registers 0 to 10
0:> mread 0-10
00:
1100 7949 0020 6051 01e1 0000 0004 2001
08:
0000 0300 0000 0000 0000 0000 0000 3000
10:
0002
3. Read 5 MII registers start from register 0
0:> mread 0 5
00:
1100 7949 0020 6051 01e1
10.86 mdev
cmd: mdev
Number of read/write accesses (def=1)
Register offset
page 92
Broadcom Confidential and Proprietary