Honeywell SILENT KNIGHT RPS-2000 Installation And Operation Manual page 197

Analog/addressable fire system
Table of Contents

Advertisement

Event Description
Detector trouble
Detector trouble restore
External Reset/Silence/Fire Drill switch trouble
External Reset/Silence/Fire Drill switch trouble restore
Manual pull switch alarm
Manual pull switch alarm restore
Manual pull switch trouble
Manual pull switch trouble restore
Notification output trouble
Notification output trouble restore
Positive Alarm Sequence acknowledge switch trouble
Positive Alarm Sequence acknowledge switch trouble restore
SLC LED Module trouble
SLC LED Module trouble restore
Supervisory/Tamper alarm condition
Supervisory/Tamper alarm condition restore
Supervisory/Tamper switch trouble
Supervisory/Tamper switch trouble restore
System-based AUX1 switch alarm
System-based AUX1 switch alarm restore
System-based AUX1 switch trouble
System-based AUX1 switch trouble restore
System-based AUX2 switch alarm
System-based AUX2 switch alarm restore
System-based AUX2 switch trouble
System-based AUX2 switch trouble restore
Water flow switch alarm
Water flow switch alarm restore
Water flow switch trouble
Water flow switch trouble restore
Zone-based acknowledge switch trouble
Zone-based acknowledge switch trouble restore
Zone-based AUX1 switch alarm
Zone-based AUX1 switch alarm restore
Zone-based AUX1 switch trouble
Zone-based AUX1 switch trouble restore
Zone-based AUX2 switch alarm
Zone-based AUX2 switch alarm restore
Zone-based AUX2 switch trouble
Zone-based AUX2 switch trouble restore
Point Events
An unexpected SLC device has been detected
An unexpected SLC device has been removed
Auxiliary power disabled
Auxiliary power enabled
Auxiliary power Trouble
151430
SIA Reporting Format
SIA pi Modifier (same as IFP-1000 Rev 9)
Module ID #
SIA Event
Parameter
(If Any)
Codes
FT
Zone #
FJ
Zone #
UT
Zone #
UJ
Zone #
FA
Zone #
FH
Zone #
FT
Zone #
FJ
Zone #
FT
Zone #
FJ
Zone #
FT
Zone #
FJ
Zone #
ET
Zone #
ER
Zone #
SS
Zone #
SR
Zone #
ST
Zone #
SJ
Zone #
UA
Zone #
UH
Zone #
UT
Zone #
UJ
Zone #
UA
Zone #
UH
Zone #
UT
Zone #
UJ
Zone #
SA
Zone #
SH
Zone #
ST
Zone #
SJ
Zone #
FT
Zone #
FJ
Zone #
UA
Zone #
UH
Zone #
UT
Zone #
UJ
Zone #
UA
Zone #
UH
Zone #
UT
Zone #
UJ
Zone #
Note:
For IDP devices, sensors 1–159 are reported as Points 1–159, modules 1–159 are reported as Points 201–359.
pi Exp. ID
XE
Point #
pi Exp. ID
XI
Point #
pi Exp. ID
FB
Point #
pi Exp. ID
FU
Point #
pi Exp. ID
FT
Point #
firealarmresources.com
Contact ID Reporting Format
SIA IFP-2000
Fixed Length Format
NN - panel ID
XX - SBUS ID
Qualifier
ZZZ - zone #
PPPP - Point #
AAAAAA-account #
FTNN000ZZZ
1
FJNN000ZZZ
3
UTNN000ZZZ
1
UJNN000ZZZ
3
FANN000ZZZ
1
FHNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
ETNN000ZZZ
1
ERNN000ZZZ
3
SSNN000ZZZ
1
SRNN000ZZZ
3
STNN000ZZZ
1
SJNN000ZZZ
3
UANN000ZZZ
1
UHNN000ZZZ
3
UTNN000ZZZ
1
UJNN000ZZZ
3
UANN000ZZZ
1
UHNN000ZZZ
3
UTNN000ZZZ
1
UJNN000ZZZ
3
SANN000ZZZ
1
SHNN000ZZZ
3
STNN000ZZZ
1
SJNN000ZZZ
3
FTNN000ZZZ
1
FJNN000ZZZ
3
UANN000ZZZ
1
UHNN000ZZZ
3
UTNN000ZZZ
1
UJNN000ZZZ
3
UANN000ZZZ
1
UHNN000ZZZ
3
UTNN000ZZZ
1
UJNN000ZZZ
3
XENNXXPPPP
1
XINNXXPPPP
3
FBNNXXPPPP
1
FUNNXXPPPP
3
FTNNXXPPPP
1
Reporting
Event
Group #
Contact #
Code
373
00
Zone #
373
00
Zone #
373
00
000
373
00
000
115
00
Zone #
115
00
Zone #
373
00
Zone #
373
00
Zone #
320
00
Group #
320
00
Group #
373
00
Zone #
373
00
Zone #
333
00
000
333
00
000
203
00
Zone #
203
00
Zone #
373
00
Zone #
373
00
Zone #
140
01
000
140
01
000
373
01
000
373
01
000
140
02
000
140
02
000
373
02
000
373
02
000
113
00
Zone #
113
00
Zone #
373
00
Zone #
373
00
Zone #
373
02
Zone #
373
02
Zone #
140
01
Zone #
140
01
Zone #
373
01
Zone #
373
01
Zone #
140
02
Zone #
140
02
Zone #
373
02
Zone #
373
02
Zone #
380
Exp. ID
Point #
380
Exp. ID
Point #
571
Exp. ID
Point #
571
Exp. ID
Point #
320
Exp. ID
Point #
11-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silent knight ifp-2000

Table of Contents