Honeywell SILENT KNIGHT RPS-2000 Installation And Operation Manual page 196

Analog/addressable fire system
Table of Contents

Advertisement

IFP-2000 Installation Manual
Event Description
Local programming begin
Local programming ended normally
Network node trouble (panel missing)
Network node trouble restore (panel no longer missing)
Phone line 1 trouble detected
Phone line 1 trouble restore
Phone line 2 trouble detected
Phone line 2 trouble restore
Printer is offline trouble
Printer is offline trouble restore
Printer is out of paper trouble
Printer is out of paper trouble restore
Remote programming aborted or ended with errors
Remote programming ended normally
Repeater ground fault trouble
Repeater ground fault trouble restore
Repeater missing trouble
Repeater missing trouble restore
Repeater Rx1 communication trouble
Repeater Rx1 communication trouble restore
Repeater Rx2 communication trouble
Repeater Rx2 communication trouble restore
SBUS Class A supervision lost
SBUS Class A supervision restore
SBUS expander trouble
SBUS expander trouble restore
SLC class A supervision trouble
SLC class A supervision trouble restore
SLC programming ended, system active
SLC programming started, system shut down
SLC short circuit trouble
SLC short circuit trouble restore
Time changed event
Unable to report to account trouble
Unable to report to account trouble restore
User access code changed
User initiated manual dialer test
VIP VCM trouble events
VIP VCM trouble restore events
Walk test begin
Walk test end
Zone Events
Auxiliary power trouble
Auxiliary power trouble restore
Detector alarm
Detector alarm restore
11-2
SIA Reporting Format
SIA pi Modifier (same as IFP-1000 Rev 9)
Module ID #
SIA Event
Parameter
(If Any)
Codes
LB
0
LS
0
EM
Panel ID
EN
Panel ID
LT
1
LR
1
LT
2
LR
2
VZ
Exp ID
VY
Exp ID
VO
Exp ID
VI
Exp ID
RU
0
RS
0
EM
0103
EN
0103
EM
0100
EN
0100
EM
0101
EN
0101
EM
0102
EN
0102
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
ET
Exp. ID
ER
Exp. ID
TE
0
TS
0
ET
Exp. ID
ER
Exp. ID
JT
0
RT
Acct #
YK
Acct #
JV
0
RX
0
ET
Exp. ID
ER
Exp. ID
TS
0
TE
0
FT
Zone #
FJ
Zone #
FA
Zone #
FH
Zone #
firealarmresources.com
Contact ID Reporting Format
SIA IFP-2000
Fixed Length Format
NN - panel ID
XX - SBUS ID
Qualifier
ZZZ - zone #
PPPP - Point #
AAAAAA-account #
LBNN000000
1
LSNN000000
1
EMNN000000
1
ENNN000000
3
LTNN000001
1
LRNN000001
3
LTNN000002
1
LRNN000002
3
VZNNXX0000
1
VYNNXX0000
3
VONNXX0000
1
VINNXX0000
3
RUNN000000
1
RSNN000000
1
EMNN000103
1
ENNN000103
3
EMNN000100
1
ENNN000100
3
EMNN000101
1
ENNN000101
3
EMNN000102
1
ENNN000102
3
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
ETNNXX0000
1
ERNNXX0000
3
TENN000000
3
TSNN000000
1
ETNNXX0000
1
ERNNXX0000
3
JTNN000000
1
RTNNAAAAAA
1
YKNNAAAAAA
3
JVNN000000
1
RXNN000000
1
ETNNXX0000
3
ERNNXX0000
1
TSNN000000
1
TENN000000
3
FTNN000ZZZ
1
FJNN000ZZZ
3
FANN000ZZZ
1
FHNN000ZZZ
3
Event
Group #
Contact #
Code
627
00
000
628
00
000
334
00
000
334
00
000
351
00
001
351
00
001
352
00
002
352
00
002
336
Exp. ID
000
336
Exp. ID
000
335
Exp. ID
000
335
Exp. ID
000
413
00
000
412
00
000
334
NN
103
334
NN
103
334
NN
100
334
NN
100
334
NN
101
334
NN
101
334
NN
102
334
NN
102
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
333
Exp. ID
000
331
Exp. ID
000
331
Exp. ID
000
607
00
000
607
00
000
332
Exp. ID
000
332
Exp. ID
000
625
00
000
354
Acct #
Acct #
354
Acct #
Acct #
602
00
000
601
00
000
332
Exp. ID
000
332
Exp. ID
000
607
00
000
607
00
000
320
00
000
320
00
000
110
00
Zone #
110
00
Zone #
151430

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silent knight ifp-2000

Table of Contents