Section 5: Operation and Maintenance
May 2013
Note
Use the Rosemount Wireless LCD Part Number: 00753-9004-0002.
66
Diagnostic Button Screen 10.1: a sensor attached
to the transmitter has failed, and valid readings from
that sensor are no longer possible - check the sensor
s n s r
and sensor wiring connections - check additional
status for more detailed information of the failure
source
f a i l u r
Diagnostic Button Screen 10.2: a sensor attached
to the transmitter is degraded, readings from that
sensor may not be within accuracy specifications -
s n s r
check the process, and sensor wiring connections -
check additional status for more detailed
information of the warning source
w a r n