Table A-8. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
(25)
Digital Display
Standard
M5
PlantWeb LCD display (Requires PlantWeb housing)
(26)(26)
M7
Remote mount LCD display and interface, no cable; PlantWeb housing, SST bracket
(26)(27)(28)
M8
Remote mount LCD display and interface, 50 ft. (15 m) cable; PlantWeb housing, SST bracket
(26)(26)
M9
Remote mount LCD display and interface, 100 ft. (31 m) cable; PlantWeb housing, SST bracket
Terminal Blocks
Standard
(29)
T1
Transient terminal block
Expanded
(9)(30)
T2
Terminal block with WAGO
(9)(30)
T3
Transient terminal block with WAGO spring clamp terminals
Manifold for Remote Mount Option
Standard
F2
3-Valve Manifold, Stainless Steel
F6
5-Valve Manifold, Stainless Steel
Expanded
F1
3-Valve Manifold, Carbon Steel
F3
3-Valve Manifold, Alloy C-276
F5
5-Valve Manifold, Carbon Steel
F7
5-Valve Manifold, Alloy C-276
PlantWeb Control Functionality
Standard
(9)(31)
A01
F
OUNDATION
PlantWeb Diagnostic Functionality
Standard
(9)(31)
D01
F
OUNDATION
(9)(32)
DA2
Advanced HART Diagnostics Suite (SPM, Power Advisory, Variable & Status Log, Service & Process
Alerts)
PlantWeb Enhanced Measurement Functionality
Standard
(9)(33)
H01
F
OUNDATION
Special Configuration (Software)
Standard
(20)
C4
NAMUR Alarm and Saturation Signal Levels, High Alarm
(20)
C5
NAMUR Alarm and Saturation Signal Levels, Low Alarm
(20)
C6
Custom Alarm and Saturation Signal Levels, High Alarm
Note: A Configuration Data Sheet (00806-0100-4809) must be completed.
(20)
C7
Custom Alarm and Saturation Signal Levels, Low Alarm
Note: A Configuration Data Sheet (00806-0100-4809) must be completed.
(20)
C8
Low Alarm (Standard Rosemount Alarm and Saturation Signal Levels)
Special Configuration (Hardware)
Standard
(20)(26)
D1
Hardware Adjustment (zero, span, security)
D4
External Ground Screw
(20)(26)
DA
Hardware Adjustment (zero, span, security) and External Ground Screw
Conduit Electrical Connector
Expanded
(34)
GE
M12, 4-pin, Male Connector (eurofast
(33)
GM
A size Mini, 4-pin, Male Connector (minifast
Specifications and Reference Data
®
spring clamp terminals
fieldbus Advanced Control Function Block Suite
fieldbus Diagnostics Suite
fieldbus Fully Compensated Mass Flow Block
®
)