Emerson Rosemount 3051SAL Reference Manual page 133

Table of Contents

Advertisement

Reference Manual
00809-0200-4802, Rev BA
Table A-10. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Output Protocol
Standard
A
4–20 mA with digital signal based on HART protocol
(5)(6)
F
F
OUNDATION
(6)(7)
X
Wireless (Requires wireless options and wireless housing 5A)
Transmitter Housing Style
Standard
00
None (Customer-supplied electrical connection)
(6)(9)
01
Assemble to Rosemount 753R Web-based Monitoring Indicator
1A
PlantWeb Housing
1B
PlantWeb Housing
1C
PlantWeb Housing
1J
PlantWeb Housing
1K
PlantWeb Housing
1L
PlantWeb Housing
(6)
2A
Junction Box Housing
(6)
2B
Junction Box Housing
(6)
2C
Junction Box Housing
(6)
2E
Junction Box Housing with output for remote
display and interface
(6)
2F
Junction Box Housing with output for remote
display and interface
(6)
2G
Junction Box Housing with output for remote
display and interface
(6)
2J
Junction Box Housing
(6)
2M
Junction Box Housing with output for remote
display and interface
(6)
5A
Wireless PlantWeb Housing
(6)(10)
7J
Quick Connect (A size Mini, 4-pin male
termination)
Transmitter Performance Class
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
Standard
3
Ultra for Flow: 0.80% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited 12-year
warranty
5
Classic 2: 0.85% flow rate accuracy, 8:1 flow turndown, 5-year stability
Transmitter Performance Class
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
Standard
(11)
1
Ultra: 1.05% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-year warranty
2
Classic: 1.20% flow rate accuracy, 8:1 flow turndown, 5-year stability
(12)
3
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 10-year stability. limited 12-year
warranty
Wireless Options
(Requires option code X and Housing Style 5A)
Wireless Burst Rate
Standard
WA
User Configurable Burst Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Specifications and Reference Data
fieldbus: AI block, Link Master, Input Selector Block (Requires PlantWeb housing)
Appendix A: Specifications and reference data
(8)
Material
Conduit Entry Size
1
Aluminum
/
-14 NPT
2
Aluminum
M20 x 1.5
1
Aluminum
G
/
2
1
SST
/
-14 NPT
2
SST
M20 x 1.5
1
SST
G
/
2
1
Aluminum
/
-14 NPT
2
Aluminum
M20 x 1.5
1
Aluminum
G
/
2
1
Aluminum
/
-14 NPT
2
Aluminum
M20 x 1.5
Aluminum
G
1
/
2
1
SST
/
-14 NPT
2
1
SST
/
-14 NPT
2
1
Aluminum
/
–14 NPT
2
May 2013
Standard
Standard
Standard
Standard
Standard
Standard
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 3051shpRosemount 3051s

Table of Contents