KYOWA WGA-670B-0 Instruction Manual page 29

Instrumentation amplifier
Table of Contents

Advertisement

4-2-5-3 Block Specified Peak Hold Mode
a) For normal display mode
• Press the HOLD key and after the lapse of delay time, the peak value is indicated.
Press the HOLD key the 2nd time and the peak value is kept hold.
Press the HOLD key the 3rd time and the peak hold mode is canceled.
• Or, when the [HOLD] signal from rear terminal board is turned ON (close) and after the lapse of delay
time, the peak value is indicated until the [HOLD] signal is turned OFF.
If the [HOLD] signal is turned OFF (open), the indicated value is kept hold.
When the [RESET] signal from the rear terminal board is turned ON (close), the peak hold mode is
canceled.
HOLD signal
RESET signal
Note) Even if no RESET signal is issued, it is reset with the next HOLD
signal.
Press the
HOLD-SW
Indicated
  value
Detecting peak
  value
Delay time
[HOLD] LED ON
Close
24
Press the
Press the
HOLD-SW
HOLD-SW
Holding
[HOLD] LED flickers
Close