Setting The Sensor Current - Novexx Solutions 64 Series User Manual

Hide thumbs Also See for 64 Series:
Table of Contents

Advertisement

01/13 Rev. 5.05-01
1. Select parameter
2. Press the ENTER button
3. Repeatedly press the CUT button
4. Set the rewinder pot. (Fig. 1) so
5. Move the bouncer arm to the final
*) The value with the bouncer arm in its final position must be at least 100 higher than the
USER MANUAL
Rewinder 2000

Setting the sensor current

Befor using the rewinder for the first time, the sensor current must be set by
a potentiometer at the rewinder (see Fig. 1).
Pot. (P101)
Turn clockwise =>
Sensor current increases
Displayed value decreases
Fig. 1 The pot. can be accessed through a slot in the back cover of the rewinder.
Action
OTHR >
until
that a value between 20 and 30 is
displayed.
position (towards the support leg).
Check the displayed value*.
value in zero position, which was set in step 4. Most important ist the difference between the
two values in the two end positions: the difference must equal/be higher than 100, ideally
110. Repeat step 4 and set a higher value in the zero position, if the difference is too little.
Rewinder (section)
Display
Note
SCHK.
SCHK
Pxxx
Other information may be
displayed depending on the
printer type; xxx = variable value.
Wxxx
Bouncer arm in zero position
W20
(Fig. 2); 24 = set value.
141 = set value (example) in the
W141
final position; Value difference =
117 (o.k.)
Attachment, Setup
Turn counter-clockwise =>
Sensor current decreases
Displayed value increases