01/13 Rev. 5.05-01
•
•
1. Select parameter
2. Press the Feed button
USER MANUAL
Rewinder 2000
Checking the sensor current setting
(Only for 64-xx and AP 5.4)
SERVICE FUNCTION > Rewinder
Call
Rewinder Values
xxx <--------------------> yyy
xxx = Sensor value in zero position
yyy = Sensor value in final position (Dancer arm at the printer side limit)
The difference yyy – xxx must at least be 80 (best: 100). If the difference is
less, the sensor current setting must be changed, see chapter Setting the
sensor current below.
Setting the sensor current
Befor using the rewinder for the first time, the sensor current must be set by
a potentiometer at the rewinder (see Fig. 3).
Pot. (P101)
Turn clockwise =>
Sensor current increases
Displayed value decreases
Fig. 3 The pot. can be accessed through a slot in the back cover of the rewinder.
Action
SERVICE
FUNCTION > Sensor
test.
repeatedly until
values.
Rewinder (section)
Display
Sensor test
Sens: 0.01
xxx
Sensor test
Sens: 4.01
xxx
Attachment, Setup
Turn counter-clockwise =>
Sensor current decreases
Displayed value increases
Note
xxx is the value
supplied by the
sensor
4.01 = sensor
peripheral devices
12