Saving Results; Releasing - norbar ET2-72-1000-110 Operator's Manual

Table of Contents

Advertisement

Saving Results

Auto Reset =
X
NOTE:
The Save icon will be shown in red when the tool is in 'Logging' mode. See EvoLog operators
manual (part number 34427) for more details.

Releasing

1.
Fit the EvoTorque
TIP:
For added safety it is recommended to secure the socket to the drive square.
This is often achieved using a pin and O ring, see socket manufacturer for guidance.
2.
Ensure the clockwise/counter-clockwise display arrow is correct.
Press
to set direction.
3.
Rotate the handle into a convenient position relative to the reaction bar.
Fit the tool onto the fastener to be released with the reaction bar
adjacent to the reaction point. See figure 55.
4.
Adopt a posture to counteract normal or unexpected
movement of the tool due to reaction forces.
5.
Press and release trigger to slowly bring reaction bar into
contact with the reaction point.
6.
Fully press the trigger and keep fully pressed until the
threaded fastener releases.
TIP:
If unable to release the fastener, increase the target torque.
The tool will automatically limit itself to the maximum tool output torque.
26
Button Operation (after a successful tightening)
Press either the
complete) reading and reset the tool, ready for the next tightening
operation.
Press the
button will reset the tool ready for the next tightening
operation
without
saving the (joint complete) reading.
Press the
button to toggle between Save and No Save.
When the Save icon
reading will be saved and automatically reset the tool ready for the next
tightening operation after the 'Hold Time' setting has expired.
The next displayed (joint complete) reading will
not shown.
®
2 with the correct size impact or high quality socket to suit the fastener to be released.
or
buttons to Save the displayed (joint
is displayed, the next displayed (joint complete)
not
be saved if the icon is
FIGURE 55 – Anti-Clockwise Operation