Connecting Supply

WARNING:
WARNING:
WARNING:
Connect plug to local mains supply.
TIP:
Supply Circuit Breaker:
If the mains supply is fitted with a circuit breaker ensure it is TYPE C (as defined in IEC / EN
60898-1) or above to eliminate false trips.
To maintain the environmental rating the tool has been factory fitted with a suitable plug to IEC 60309.
The plug will either be coloured blue (for 230 V a.c. models) or yellow (for 110 V a.c. models).
It is important to connect directly to a local supply socket outlet of the same type.
TIP:
Use of a Different Local Supply Socket:
The tool is supplied with a plug rated to IEC 60309 for industrial locations.
An adaptor (where supplied) can be used to convert to a non-industrial plug; see
INTRODUCTION for plug options.
Should a different plug be required, the mains cable colours are:
BROWN-LIVE
The new plug must have a ground (EARTH) connection.
Ensure the plug is rated for voltage/current of tool.
If in doubt consult a qualified electrician.
TIP:
Minimum Power Requirement:
Use tool on either a quality mains (grid) supply or a generator rated at 5KVA minimum.
Other power sources, like local networks, may not be adequate to power the tool.
Use 230V tool if possible as they are subject to less cable voltage drop and able to withstand
larger drops in voltage.
Use tool close to power outlet, if an extension cable is required observe the following
limitations:
For 110V tools use Ø1.5mm² / 14 AWG cable up to 25m or Ø2.5mm² / 10 AWG cable up to 75m.
For 230V tools use Ø1.5mm² / 14 AWG cable up to 50m or Ø2.5mm² / 10 AWG cable up to 100m.
Ensure extension cable is made up in a maximum of two (2) separate lengths to reduce plug /
socket connections.
Ensure extension cable is completely unwound.
The above requirement is for using 1 tool.
THE TOOL HAS BEEN DESIGNED FOR ONE VOLTAGE ONLY.
CHECK THAT THE POWER SUPPLY CORRESPONDS TO THE VOLTAGE ON
THE TOOL RATING PLATE.
THE TOOL MUST BE EARTHED
ENSURE POWER SUPPLY HAS AN EARTH
DO NOT OPERATE WITHOUT AN EARTH
FOR OPERATOR SAFETY ENSURE THE MAINS SUPPLY HAS A RESIDUAL
CURRENT DEVICE (RCD). TEST THE RCD REGULARLY.
BLUE-NEUTRAL
GREEN/YELLOW-EARTH