Expand Ean 8 To Ean 13; Ean 8 Minimum Reads - Datalogic Cobalto CO5330 Product Reference Manual

On-counter omnidirectional presentation
Table of Contents

Advertisement

EAN 8

Expand EAN 8 to EAN 13

Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.
DEFAULT
$C8B3B01
Expand EAN 8 to EAN 13 = Enable

EAN 8 Minimum Reads

This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must
be decoded before it is accepted as good read.
DEFAULT
$C8BMR02
EAN 8 Minimum Reads = 2
$C8BMR04
EAN 8 Minimum Reads = 4
Product Reference Guide
Enter/Exit Programming Mode
$C8B3B00
Expand EAN 8 to EAN 13 = Disable
$C8BMR01
EAN 8 Minimum Reads = 1
$C8BMR03
EAN 8 Minimum Reads = 3