Environmental Specifications - Emerson Rosemount 2160 Reference Manual

Wireless level detector
Hide thumbs Also See for Rosemount 2160:
Table of Contents

Advertisement

Reference Manual
00809-0100-4160
A.6

Environmental specifications

A.6.1
Maximum operating pressures
Figure A-1: Operating Pressures
1450 (100)
1160 (80)
-14.5 (-1.0)
A. Process pressure, psig (barg)
B. Process temperature, °F (°C)
The final rating depends on the process-wetted connection.
Threaded process connection
See
Figure
Hygienic process connection
435 psig (30 barg)
Flanged process connection
The maximum operating pressure is the lower of the process pressure
flange pressure rating (see
Table A-2: Maximum Flange Pressure Rating
Flange standard
ASME B16.5 Class 150
ASME B16.5 Class 300
ASME B16.5 Class 600
EN1092-1 PN 10/16
EN1092-1 PN 25/40
EN1092-1 PN 63
EN1092-1 PN 100
(1)
ASTM stainless steel.
(2)
At 100 °F (38 °C), the pressure rating decreases with an increasing process temperature.
(3)
At 122 °F (50 °C), the pressure rating decreases with an increasing process temperature.
Rosemount 2160 Wireless Level Detector
A
2160***S
-40
32
122
302
(-40)
(0)
(50)
(150)
A-1.
Table
A-2).
Specifications and reference data
1450 (100)
885 (61)
B
-14.5 (-1.0)
Stainless steel flanges
(2)
275 psig
(2)
720 psig
(2)
1440 psig
(3)
16 barg
(3)
40 barg
(3)
63 barg
(3)
100 barg
May 2022
A
2160***E
-94
32
100
500
(-70)
(0)
(38)
(260)
(Figure
A-1) and
(1)
B
75

Advertisement