Emerson Rosemount 2160 Reference Manual page 58

Wireless level detector
Hide thumbs Also See for Rosemount 2160:
Table of Contents

Advertisement

Service and troubleshooting
May 2022
Recommended actions
Replace the device.
Possible cause
Thick encrustation on the forks.
Recommended actions
Clean the fork with care.
6.3.3
Incorrect switching of output state
Recommended actions
Check the configuration of frequency bands.
Related information
Calibration frequencies and switch points
6.3.4
Faulty switching
Symptom or indication
Turbulence.
Recommended actions
Set a longer switching time delay.
Symptom or indication
Excessive electrical noise.
Recommended actions
Suppress the cause of the interference.
Related information
Sensor output delay
6.3.5
Wireless network troubleshooting
The device is not joining the wireless network
Recommended actions
58
1. Verify Network ID and Join Key. The Network ID and Join Key in the device must
match the Network ID and Join Key of the Gateway.
2. Enable High Speed Operation on the Wireless Gateway.
3. Check Power Module.
4. Verify that Active Advertising has been enabled on the Wireless Gateway.