Postrequisites
If the device is not to be commissioned yet, remove the power module and fasten the
housing cover. This is to conserve power module life and to ensure safe transportation.
The power module should be inserted only when the device is ready to be commissioned.
4.4.6
Verify device joins network
Network connection can be verified in four ways, further described in this section:
At the device display
Using the AMS Wireless Configurator
In the Wireless Gateway's integrated web interface
Using the handheld communicator
If the Rosemount 2160 was configured with the Network ID and Join Key, and sufficient
time has passed, the device should be connected to the network. It usually takes a few
minutes for the device to join the network.
Verify by device display
Procedure
1. Unscrew the device display cover.
42