Service and troubleshooting
May 2022
6.5.1
Handling considerations
The power modules with the wireless unit contains primary lithium/thionyl chloride
batteries. Under normal conditions, the battery materials are self-contained and are not
reactive as long as the batteries and the battery pack integrity are maintained. Care should
be taken to prevent thermal, electrical or mechanical damage. Contacts should be
protected to prevent premature discharge.
Use caution when handling the power module. It may be damaged if dropped from
heights in excess of 20 ft. (6 m).
Battery hazards remain when cells are discharged.
6.5.2
Environmental considerations
As with any battery, local environmental rules and regulations should be consulted for
proper management of spent batteries. If no specific requirements exist, recycling
through a qualified recycler is encouraged. Consult the Safety Data Sheet (SDS) for battery
specific information.
6.5.3
Shipping considerations
The unit was shipped to you without the power module installed. Please remove the
power module prior to shipping.
Each Black Power Module (model number 701PBKKF) contains two "C" size primary
lithium batteries. Primary lithium batteries (charged or discharged) are regulated in
transportation by the U. S. Department of Transportation, and are also covered by IATA
(International Air Transport Association), ICAO (International Civil Aviation Organization),
and ARD (European Ground Transportation of Dangerous Goods). It is the responsibility of
the shipper to ensure compliance with these or any other local requirements. Consult
current regulations and requirements before shipping.
Each Blue Power Module (A0701PBU) contains two "D" size primary lithium batteries.
Primary lithium batteries (charged or discharged) are regulated in transportation by the
U.S. Department of Transportation, and are also covered by IATA (International Air
Transport Association), ICAO (International Civil Aviation Organization), and ARD
(European Ground Transportation of Dangerous Goods). It is the responsibility of the
shipper to ensure compliance with these or any other local requirements. Please consult
current regulations and requirements before shipping.
6.6

Opening the lid (cover)

Before opening the lid for maintenance reasons observe following items:
Do not remove the lid while circuits are live.
No dust deposits or whirlings are present.
No rain can enter into the housing.