Reference Manual
00809-0100-4160
Procedure
1. Select Configure → Guided Setup.
2. Select Configure Update Rate and follow the on-screen instructions.
Related information
Wireless update rate
4.4.4
Obtain network ID and join key
In order to communicate with the Wireless Gateway, and ultimately the host system, the
Rosemount 2160 must be configured to communicate on the wireless network. This step
is the wireless equivalent of connecting wires from a device to the host system.
Procedure
From the Wireless Gateway's integrated web interface, select System Settings →
Network → Network Settings.
Figure 4-5: Gateway Network Settings
4.4.5
Enter network ID and join key
The device must be configured with the same Network ID and Join Key as the Gateway in
order to join the network.
Procedure
1. Select Configure → Guided Setup.
2. Select Join Device to Network and follow on-screen the instructions.
Rosemount 2160 Wireless Level Detector
Note
If the update rate is reconfigured, the unit will continuously update for five minutes
and then update with the reconfigured update rate.
Configuration