Download Print this page
Emerson Rosemount 2160 Quick Start Manual

Emerson Rosemount 2160 Quick Start Manual

Wireless level detector vibrating fork
Hide thumbs Also See for Rosemount 2160:

Advertisement

Quick Links

Quick Start Guide
00825-0100-4160, Rev CB
September 2020
Rosemount
2160 Wireless Level
Detector
Vibrating Fork

Advertisement

loading

Summary of Contents for Emerson Rosemount 2160

  • Page 1 Quick Start Guide 00825-0100-4160, Rev CB September 2020 ™ Rosemount 2160 Wireless Level Detector Vibrating Fork...
  • Page 2 Quick Start Guide September 2020 Contents About this guide...........................3 Installation........................... 6 Configuration..........................14 Product certifications......................... 22 Rosemount 2160 Wireless Level Detector...
  • Page 3: About This Guide

    September 2020 Quick Start Guide About this guide This Quick Start Guide provides basic guidelines for the Rosemount 2160. Refer to the Rosemount 2160 Reference Manual for more instructions. The manual and this guide are also available electronically at Emerson.com/ Rosemount.
  • Page 4 WARNING Process leaks could result in death or serious injury. • Ensure the level detector is handled carefully. If the process seal is damaged, gas might escape from the vessel (tank) or pipe. Rosemount 2160 Wireless Level Detector...
  • Page 5 September 2020 Quick Start Guide WARNING Physical access Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end users’ equipment. This could be intentional or unintentional and needs to be protected against. Physical security is an important part of any security program and fundamental to protecting your system.
  • Page 6: Installation

    Fork alignment in a vessel (tank) installation Figure 2-2: Correct Fork Alignment for Vessel (Tank) Installation A. Tri Clamp process connections have a circular notch B. Threaded process connections have a groove C. Flanged process connections have a circular notch Rosemount 2160 Wireless Level Detector...
  • Page 7 September 2020 Quick Start Guide Mounting the threaded version 2.3.1 Seal and protect the threads • Use anti-seize paste or PTFE tape according to site procedures. A gasket may be used as a sealant for BSPP (G) threaded connections. 2.3.2 Threaded vessel (tank) or pipework connection •...
  • Page 8 2. Tighten the bolts and nuts with sufficient torque for the flange and gasket. 3. Screw the level detector into the flange thread. A. Tighten using the hexagon nut only B. Gasket for BSPP (G) threaded connection Rosemount 2160 Wireless Level Detector...
  • Page 9 September 2020 Quick Start Guide Mounting the flanged version Procedure 1. Lower the level detector into the nozzle. A. Gasket (customer supplied) 2. Tighten the bolts and nuts with sufficient torque for the flange and gasket. Quick Start Guide...
  • Page 10 Quick Start Guide September 2020 Mounting the Tri Clamp version Procedure 1. Lower the level detector into the flange face. A. Seal (supplied with Tri Clamp) 2. Fit the Tri Clamp. Rosemount 2160 Wireless Level Detector...
  • Page 11 September 2020 Quick Start Guide Wireless battery installation To install the battery that supplies all power to the Rosemount 2160: Procedure 1. Remove the housing cover on the battery compartment side. 2. Connect the battery. 3. Replace the battery cover and tighten to safety specification (metal- to-metal).
  • Page 12 3. Rotate the display to the desired orientation, and snap the display into place. Note If the device display four-pin connector is inadvertently removed from the interface board, carefully re-insert the connector before snapping the device display back into place. Rosemount 2160 Wireless Level Detector...
  • Page 13 September 2020 Quick Start Guide Adjust housing orientation (optional) To improve field access to wiring or to better view the optional LCD display: Procedure 1. Loosen the set screw until the level detector housing can rotate smoothly. Do not unscrew all the way. Rotating the housing, without this screw in place, can damage the internal wiring.
  • Page 14: Configuration

    Get started with your preferred configuration tool 3.2.1 AMS Wireless Configurator The AMS Wireless Configurator is the recommended software tool for wireless network devices, and is supplied with the Emerson Wireless Gateway. Refer to the AMS Wireless Configurator Manual Supplement further information.
  • Page 15 Prerequisites The Rosemount 2160 DD is typically installed together with AMS Wireless ® Configurator. To download the latest HART DD, visit the Emerson Device Install Kit site at: Emerson.com/DeviceInstallKits...
  • Page 16 (see Figure 3-1). Get the latest Device Descriptor (DD) If the DD is not installed on a handheld communicator supplied by Emerson, see the appropriate User’s Manual available at Emerson.com/ FieldCommunicator for instructions on how to update to the latest DD.
  • Page 17 September 2020 Quick Start Guide See the Emerson Wireless Gateway Reference Manual for more information. 3.3.2 Connect to device Procedure ® 1. Connect a handheld communicator or a HART modem to the communication terminals as shown in Figure 3-1. 2. Do one of the following: •...
  • Page 18 This is to conserve power module life and to ensure safe transportation of the level detector. The power module should be inserted only when the device is ready to be commissioned. Rosemount 2160 Wireless Level Detector...
  • Page 19 Key, and sufficient time has passed, the level detector should be connected to the wireless network. It usually takes a few minutes to join the wireless network. If the wireless network has not been joined, see the troubleshooting section in the Rosemount 2160 Reference Manual.
  • Page 20 Procedure 1. Start AMS Wireless Configurator. 2. Select View → Device Connection View. 3. Double-click the device icon. 4. Select Configure → Guided Setup. 5. Select Basic Setup and follow the on-screen instructions. Rosemount 2160 Wireless Level Detector...
  • Page 21 September 2020 Quick Start Guide 3.4.2 Start Guided Basic Setup using a handheld communicator The options available in the Basic Setup wizard include all items required for basic operation. Procedure 1. Turn on the handheld communicator and connect to the level detector.
  • Page 22: Product Certifications

    All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
  • Page 23 September 2020 Quick Start Guide U.S.A. 4.6.1 Intrinsic Safety (IS), Non-Incendive (NI), Dust Ignition-proof (DIP) Summary of product certification Protections Intrinsic Safety (IS) Non-Incendive (NI) Dust Ignition-proof (DIP) Project ID 3036541 Markings IS Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G IS Class I, Zone 0, AEx ia IIC NI Class I, Division 2, Groups A, B, C, and D DIP Class II/III, Division 1, Groups E, F, and G...
  • Page 24 3. The Rosemount 2160 enclosure is made of aluminum alloy and given a protective epoxy coating; however, care should be taken to protect it from impact or abrasion if located in a Zone 0.
  • Page 25 September 2020 Quick Start Guide International 4.9.1 IECEx Intrinsic Safety (IS) Summary of product certification Protection Intrinsic Safety (IS) for gas atmospheres Certificate IECEx BAS 09.0123X Markings Ex ia IIC T5-T2 IP66 Safety Instructions for hazardous area installations (I1 and I7) instructions Special Conditions for Safe Use 1.
  • Page 26 To avoid electrostatic charge build-up, it shall not be rubbed or cleaned with solvents or a dry cloth. 3. The Rosemount 2160 enclosure is made of aluminum alloy and given a protective epoxy coating. However, care should be taken to protect it from impact or abrasion if located in Zone 0.
  • Page 27 2160X**E***********I7****** (“*” indicates options in construction, function, and materials). 1. The Rosemount 2160 may be used in a hazardous area with flammable gases and vapors with apparatus groups IIC, IIB and IIA, and temperature classes T1 to T5. The temperature class of the installation will be determined from the highest process or ambient temperature.
  • Page 28 Quick Start Guide September 2020 c. The Rosemount 2160 enclosure is made of aluminum alloy and given a protective epoxy coating; however, care should be taken to protect it from impact or abrasion if located in an area where Equipment Protection Level Ga is required (Zone 0 locations).
  • Page 29 September 2020 Quick Start Guide 4.14 EU Declaration of Conformity Figure 4-1: EU Declaration of Conformity (Page 1) EU Declaration of Conformity No: RMD 1076 Rev. I Rosemount Tank Radar AB Layoutvägen 1 S-435 33 MÖLNLYCKE Sweden declare under our sole responsibility that the product, Rosemount™...
  • Page 30 Equipment Group II, Category 1 G (Ex ia IIC T5…T2 Ga) Harmonized Standards: EN 60079-0:2018 EN 60079-11:2012 (Minor variations in design to suit the application and/or mounting requirements are identified by alpha/numeric characters where indicated * above) Rosemount 2160 Wireless Level Detector...
  • Page 31 September 2020 Quick Start Guide Figure 4-3: EU Declaration of Conformity (Page 3) EU Declaration of Conformity No: RMD 1076 Rev. I ATEX Notified Body SGS Fimko Oy [Notified Body Number: 0598] Särkiniementie 3 P.O. Box 30 FI-00211, Helsinki Finland ATEX Notified body for Quality Assurance DNV Nemko Presafe AS [Notified Body Number: 2460] Veritasveien 1...
  • Page 32 O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. 意为在该部件所使用的所有均质材料里,至少有一类均质材料中该有害物质的含量高于 GB/T 26572 所规定的限量要求. X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. Rosemount 2160 Wireless Level Detector...
  • Page 33 September 2020 Quick Start Guide Quick Start Guide...
  • Page 34 Quick Start Guide September 2020 Rosemount 2160 Wireless Level Detector...
  • Page 35 September 2020 Quick Start Guide Quick Start Guide...
  • Page 36 The Emerson logo is a Twitter.com/Rosemount_News trademark and service mark of Emerson Electric Facebook.com/Rosemount Co. Rosemount is a mark of one of the Emerson Youtube.com/user/ family of companies. All other marks are the RosemountMeasurement property of their respective owners.