Specifications and reference data
May 2022
Rotation
Rotatable housing allows correct alignment of both the forks and the omni-directional
antenna for optimal signal and best viewing position of the LCD integral display.
Ingress protection
Housing is NEMA 4X and IP66 compliant.
A.2.3
Process wetted connections
Connections
Threaded, Tri Clamp, and flanged process connection options.
Materials
316/316L stainless steel (1.4401/1.4404 dual-certified)
Hand-polished to better than 0.4 μm option for Tri Clamp connections.
Alloy C (UNS N10002) and Alloy C-276 (UNS N10276)
Available for flanged, and selected threaded process connections (¾-in. and 1-in. BSPT
(R), and ¾-in. and 1-in. NPT).
Gasket material for ¾-in. and 1-in. BSPP (G) is non-asbestos BS7531 Grade X carbon
fiber with rubber binder.
Gaskets are not supplied with flanged process connections.
A.2.4
Customer specified fork length
Table A-1: Extended Fork Lengths
Process connection
¾-in. threaded
1-in. threaded
Flanged
Tri Clamp
(1)
Maximum extended length of fork with hand-polished option is 39.4 in. (1000 mm).
A.3

Performance specifications

A.3.1
Electromagnetic Compatibility (EMC)
All versions of the Rosemount 2160 meet all relevant requirements of EN 61326.
72
Minimum
3.8 in. (95 mm)
3.7 in. (94 mm)
3.5 in. (89 mm)
4.1 in. (105 mm)
Reference Manual
00809-0100-4160
(1)
Maximum
118.1 in. (3000 mm)
118.1 in. (3000 mm)
118.1 in. (3000 mm)
118.1 in. (3000 mm)
Reference Manual