Interval: Set the counting time interval, when it is more than the time interval, the flow counter will
reset and enter into next counting period automatically. The maximum is 3600 seconds; 0= Ignore.
Threshold: Set the upper limit value for target counting, the alarm will be triggered automatically
when the value is more than the setting.
Total Counter: Enable or disable the Total Counter function.
Time: Set the effective time period for the day of total counter.
Alarm Threshold: Set the upper limit value for the day of total flow, the alarm will be triggered
automatically when the value is more than the setting.
Target Percent: Setup the minimum percentage ration (target size/ image area) of effective counting
targets. Once the targets ration is smaller than the setting value, the system will ignore the target
which passing through the trigger line.
Email: Check "Email" and once the event triggers that it will send Email to setting email address.
Snap: Check "Snap" and once the event triggers that it will linkage camera to snapshot picture and
save on the SD card.
Record: Check "Record" and once the event triggers that it will linkage camera to save the video on
the SD card.
Alarm Output: Check "Alarm output" and once the event triggers, the camera will linkage to alarm
output.
PTZ: Check "PTZ" and once the event triggers, the camera will linkage PTZ camera to move the
assign Preset point.
Preset: Setup the Preset point for the PTZ camera move to when the event is triggered.
Snap Interval: Setup the snapshot interval time.
Snap Number: Setup the snapshot image count for each event triggers.
Save: Click "Save" icon to store the setting.
46